A typical single garage of about 3 by 6 metres needs one 1,200 mm LED batten of around 4,000 lumens for parking and storage, or about three if you work at a bench. A double garage of about 6 by 6 metres needs two battens for general use and five to six for a workshop. Mount them running the length of the garage, between the parking bays rather than above the car roofs, so light reaches the sides of the car and the walls where you store things.
This guide shows how to work out the number for your own garage, where to put the battens, and which features are worth paying attention to, such as sensors and weatherproof ratings.
What is a batten light?
A batten light is a long, slim fitting mounted directly onto the ceiling or wall. The name comes from the old fluorescent tube battens that lit garages, laundries and workshops for decades. An LED batten does the same job with LEDs built in, so there are no tubes or starters to replace.
Do not confuse an LED batten with a batten fix light. A batten fix is a decorative shade or fitting that mounts onto a standard ceiling lampholder and takes a globe. Batten fix lights suit hallways and bedrooms, but for even, bright light across a garage, a proper LED batten is the better tool. Browse the full range of batten lights to compare lengths and outputs.
How many LED battens do you need?
Work it out in three steps.
- Measure the floor area. Multiply length by width. A 3 by 6 metre single garage is 18 square metres.
- Decide what the garage is for. Parking and storage need general light. A workbench, hobby space or home gym needs much more.
- Divide by the batten's output. Check the lumens on the listing. Many 1,200 mm LED battens in our range give between about 3,600 and 4,250 lumens, but some give less, so always check.
As a rule of thumb, allow about 200 lumens per square metre for parking and storage, and around 600 lumens per square metre or more for workshop use. The extra allows for light lost to walls, shelving and the car itself.
| Garage | Floor area | Parking and storage | Workshop or gym |
|---|---|---|---|
| Single, 3 x 6 m | 18 m² | 1 batten (about 3,600 lm needed) | 3 battens (about 10,800 lm needed) |
| Double, 6 x 6 m | 36 m² | 2 battens (about 7,200 lm needed) | 5 to 6 battens (about 21,600 lm needed) |
| Large double, 6 x 9 m | 54 m² | 3 battens (about 10,800 lm needed) | 8 battens (about 32,400 lm needed) |
These figures assume 1,200 mm battens of around 4,000 lumens. Dark walls, a high ceiling or a crowded space push the number up; white walls push it down. If in doubt, round up: it is easier to switch one batten off than to add another later.
Where to put them
- Run them lengthways, parallel to the cars, so each batten lights the full depth of the garage.
- Place them between parking bays, or between the car and the wall, rather than directly over the car roof. Light then falls on the doors, the boot and the floor around the car.
- Light the bench from the front. Put a batten above the front edge of the workbench, not behind you, so your body does not cast a shadow over your work.
- Keep clear of the door. Check where the roller or tilt door and its opener sit when open, and position battens so the door does not block them.
- Light the storage walls. If shelves line one wall, a batten about a metre out from it lights the shelves without glare.
Features worth checking
Brightness and length
The Telbix Edge LED batten in the 1,200 mm size draws 40 W for 4,000 lumens, a genuine work-light output from a single fitting. The Mercator Neo CCT batten gives 3,600 lumens from its 40 W, 1,200 mm version and screws straight to the ceiling without a bracket.
Colour temperature
Cooler white helps you see detail and colour at a bench. Many battens let you choose on site: the Edge switches between 3000K, 4500K and 6500K, and the Neo between 3000K, 4000K and 5000K. For a garage that doubles as a workshop, 4000K to 5000K is a common choice.
Damp and dusty garages
The Edge is rated IP20, which means indoor, dry locations only. If your garage is open to the weather, gets damp, or you wash things down, choose a sealed batten. The Domus BOLT is IP44 from the underside once installed, and in its 1,200 mm size gives 1,850 or 3,800 lumens at 4000K depending on a wattage switch set at installation. For tougher conditions, the Domus HYDRO-120 is IP65 and IK10 rated, giving between 4,050 and 4,250 lumens on its 30 W setting.
Sensors
A sensor batten turns on as you walk in with your hands full. Domus offers its PARK-120-DIFF and HYDRO battens with no sensor, an on/off microwave sensor, or a dimming sensor that holds a low background level and lifts to full when it detects movement. The listings note that a separate remote is needed to change the sensor's factory settings, so order it with the battens. Our sensor and security lighting guide explains the options in more detail.
Dimming
Many battens are not dimmable, including the Edge, the Neo and the BOLT. If you want a lower setting for everyday use, a dual-wattage batten such as the BOLT can be set to half output at installation instead.
Installation
Most LED battens are hard-wired. The Edge, for example, is a Class I fitting that needs an earth connection, so it is an electrician's installation rather than a plug-in. If you are replacing old fluorescent battens, your electrician can usually mount new LED battens in the same positions, then add more if the count above says you need them.
Outside the garage
A flood light over the garage door or driveway makes arriving at night easier and safer. See our range of flood lights. For a large shed or a workshop with a high roof, battens may not be enough; our high bay lighting guide covers lighting for taller spaces.
Frequently asked questions
How many LED battens do I need for a single garage?
One 1,200 mm batten of around 4,000 lumens is usually enough for parking and storage in a 3 by 6 metre garage. Allow about three if you use it as a workshop.
How many LED battens for a double garage?
Two battens for general use in a 6 by 6 metre garage, and five to six if you work in there.
What colour temperature is best for a garage?
Neutral to cool white, about 4000K to 5000K, is a common choice because it shows detail and colour clearly. Many battens let you switch colour temperature on site.
Should garage battens go above the car?
Generally no. Put them between parking bays or between the car and the walls so light reaches the sides of the car and the floor around it.
Can I install an LED batten myself?
Most LED battens are hard-wired to mains power and must be installed by a licensed electrician.
Get help planning your garage
Send us your garage measurements, or drop into the Lights For You showroom in Ashfield, Sydney, and we can suggest a batten count and layout that suits the way you use the space.



