Bar Lights
Batten Lights
Batten Fix Lights(DIY)
Bedside Table Lamps
Cabinet Lights
Ceiling Lights
Chandeliers
Close to Ceiling Light (CTC)
Copper Lights
Emergency Lighting
Fairy Lights
Floor Lamps
High Bay Lights (UFO)
Lamps
Mirror Lights
Oyster Lights
Pendants Lighting
Plaster Wall Lights
Smart Lights
Spot Lights
Table Lamps
Touch Table Lamps
Up/Down Wall Lights
Vanity Lights
Wall Lights
LED Strips
LED Strips Controller
Batten Lights
Bollard Lighting
Brick Lights
Bunker Lights
Coach Lighting
Deck Lights
Driveway Lights
Fairy Lights
Flood Lights
Garden Lighting
Inground Lights
Pathway Lighting
Pillar Mount
Pond Lights
Posts Lights/Top
Outdoor Ceiling Lights
Outdoor Sensor Lights
Outdoor Wall Lights
Solar Lights
Spike Lights
Step Lights
Up/Down Wall Lights
Clearance Sale
LoginCouldn't load pickup availability
The Split is a 5 W recessed inground uplighter in 316 stainless steel, and this listing sells the mains part, HV1842T-240V. It drops into a canister below ground level and finishes flush with the surface behind a clear tempered-glass face with an anti-glare honeycomb louvre. It is trafficable to 1000 kg, so it will take a car in a driveway or a path.
This part takes a 240 V AC mains supply directly. There is no transformer and no low-voltage stage anywhere in it. ⛔ It is Protection Class I and it requires an earth: Havit's installation step for this exact part number reads use wire with earth, connect the earth first, then live and neutral. ⚠ Havit's data sheet covers this model and its low-voltage siblings in one undivided block and prints no earth required across all of them — the per-model table in the installation sheet and the wiring step for this part number both say otherwise, and this page follows those. Wiring is parallel, and the job is one for a qualified electrician working to AS/NZS 3000 with the circuit isolated first.
The built-in LED is tri-colour: 3000K, 4000K and 5500K, giving 400 lm, 430 lm and 450 lm respectively, through a 60° beam at CRI >80. ⚠ The selector is a switch on the bottom of the fitting, inside a sealed brass cover, so on a recessed light you choose the colour temperature before you drop it into the canister — changing it afterwards means lifting the fitting out and re-sealing the cover. There is no globe and no socket, so nothing is ever replaced, and lamp expectancy is >30,000hrs.
It is IP67 and IK10 behind a clear glass diffuser, with a 300 mm tail. ⛔ Adequate drainage under the canister is a warranty condition rather than a recommendation — Havit asks for 100–150 mm of crushed rock and a slight fall on the surrounding ground so water runs away, and states that if no drainage is allowed the warranty is void. The anti-syphon plug and the male and female connector supplied on the cable must both remain on it for the warranty to be valid. All o-rings and seals must be seated, every joint soldered and sealed watertight, and silicone run around the edge of the fitting once it is in. ⚠ 316 stainless still needs regular cleaning to stop tea staining forming, and tea staining is not covered by the warranty — Havit's HV9971 maintenance kit is made for it. A security face with screws is available separately as HV1842-F-SH. Every figure on this page for HV1842T-240V was taken by Lights For You from the HV1842 data sheet (AUG24), the current HV1842T / HV1842RGBW installation instructions and Havit's own listing for this model, which states a 3 Years Replacement Warranty.
No. HV1842T-240V takes a 240 V AC mains supply directly — nothing sits between it and the circuit. That is the whole difference between this part number and the low-voltage part Havit sells alongside it.
Yes. This part is Protection Class I and requires an earth. Havit's installation step for this part number is explicit: use wire with an earth and connect the earth first, then live and neutral. ⚠ The data sheet's shared specification block prints no earth required because it covers the low-voltage models in the same undivided row — the per-model table and the wiring step are the ones that apply here.
⚠ Ask us first. Havit's data sheet and its installation sheet do not agree with each other on this part number, and we would rather check with the supplier than publish a guess on a mains fitting. Send us the part number and the dimmer you have in mind and we will confirm it before you buy.
A switch on the bottom of the fitting, inside a sealed brass cover. Choose 3000K, 4000K or 5500K, re-seat the cover tightly, and do it before the fitting goes into the canister — afterwards the switch is under the light and under the ground.
Yes. Havit rates the Split at 1000 kg trafficable and it is IK10, the top of the impact scale. The canister still has to be set level with the finished surface; Havit makes that a warranty condition in its own right.
100–150 mm of crushed rock beneath the canister and a slight fall on the surrounding ground so water runs away. Havit states that if no drainage is allowed the warranty is void, and standing water is the most common way a recessed fitting fails.
Yes. Havit requires regular cleaning maintenance on all 316 stainless fittings to avoid tea staining, and states that tea staining is not covered by the warranty. Rinsing and wiping the face when you clean the path is usually enough; HV9971 is Havit's own kit for the heavier cases.
| Range | Split |
|---|---|
| Part number | HV1842T-240V |
| Product type | Recessed inground uplighter, round |
| Material | 316 stainless steel |
| Finish | Stainless steel |
| Installation type | Ground — recessed, in a canister |
| Input voltage | 240V AC mains supply |
| Transformer required | None — it wires to the mains supply directly |
| Protection class | Class I — earth required |
| Lamp base | Built-in LED — no globe, no socket |
| Lamp wattage | 1 x 5W |
| Colour temperature | 3000K / 4000K / 5500K, set on a switch on the underside inside a sealed brass cover |
| Lumen output | 400 lm at 3000K · 430 lm at 4000K · 450 lm at 5500K |
| Beam angle | 60° |
| CRI | >80 |
| Lamp expectancy | >30,000hrs |
| IP rating | IP67 |
| IK rating | IK10 |
| Trafficable | 1000 kg |
| Diffuser | Clear glass with anti-glare honeycomb lens |
| Cable length | 300 mm |
| Dimmable | Not stated — Havit’s data sheet and its installation sheet disagree for this part number, so ask us before specifying a control |
| Wiring | Parallel |
| Drainage | 100–150 mm of crushed rock beneath the canister — a warranty condition |
| Maintenance | Regular cleaning; tea staining is not covered by the warranty |
| Optional accessories | HV1842-F-SH security face with screws · HV9971 stainless maintenance kit |
| Warranty | 3 Years Replacement |
| Part number | Input voltage | Protection class | Colour temperature | Lumen output | Beam angle |
|---|---|---|---|---|---|
| HV1842T-240V | 240V AC | Class I — earth required | 3000K / 4000K / 5500K | 400 lm / 430 lm / 450 lm | 60° |
For all warranty claims please ensure you have your proof of purchase at hand, an invoice from your electrician from the installation and check the faulty product is within the applicable warranty period. Warranty is replacement only.
Lights For You is not responsible for damages caused by unprofessional installation, modified products or manipulated by the customer or by any other person not authorised by the manufacturer; as well as by improper use, manipulation and/or short circuits, apparent signs of improper treatment.
Notification of any damages or missing items must be received by Lights For You within seven (7) days of receipt of the product. Please email photos to ashfield@lightsforyou.com.au.
If the product is to be repaired or replaced, it must correspond to the one originally sent by Lights For You and the customer must include the delivery note and/or invoice.
You must lodge a return request via the below request form.
Credits will be issued in the form of store credit or gift voucher and will be equal to the price paid for the product minus the cost of shipping. Store credit vouchers are valid for six months from the date of issuance.
We reserve the right to refuse a return in cases where we cannot be reasonably satisfied that you purchased the product from us or where we are not responsible for the damage in accordance with our Faults & damages policy.
Customers who wish to cancel all or part of an order due to change of mind or incorrectly ordered may do subject to cancelling in within 12 hours, during business hours from time of purchase. Once products have been shipped, you cannot cancel them.
Please refer to the following link to learn more about our policies
Learn MoreThanks for subscribing!
This email has been registered!
| Product | SKU | Product type | Other details |
|---|