Bar Lights
Batten Lights
Batten Fix Lights(DIY)
Bedside Table Lamps
Cabinet Lights
Ceiling Lights
Chandeliers
Close to Ceiling Light (CTC)
Copper Lights
Emergency Lighting
Fairy Lights
Floor Lamps
High Bay Lights (UFO)
Lamps
Mirror Lights
Oyster Lights
Pendants Lighting
Plaster Wall Lights
Smart Lights
Spot Lights
Table Lamps
Touch Table Lamps
Up/Down Wall Lights
Vanity Lights
Wall Lights
LED Strips
LED Strips Controller
Batten Lights
Bollard Lighting
Brick Lights
Bunker Lights
Coach Lighting
Deck Lights
Driveway Lights
Fairy Lights
Flood Lights
Garden Lighting
Inground Lights
Pathway Lighting
Pillar Mount
Pond Lights
Posts Lights/Top
Outdoor Ceiling Lights
Outdoor Sensor Lights
Outdoor Wall Lights
Solar Lights
Spike Lights
Step Lights
Up/Down Wall Lights
Clearance Sale
LoginCouldn't load pickup availability
The Domus Track 3-Circuit Emergency Kit is a D40-classified emergency luminaire on a track adaptor — for 3-circuit track, in black or white.
⭐⭐ THIS IS THE QUESTION THE PRODUCT RAISES AND THE LISTING DOES NOT ANSWER. ⭐ An emergency luminaire needs a permanent live to keep its battery charged, while the whole point of a 3-circuit track is that circuits are switched. ⭐ A fitting on a circuit that is switched off overnight is a fitting whose battery is charging only during trading hours. ⭐ THE USUAL ANSWER IS TO DEDICATE ONE CIRCUIT AS PERMANENTLY LIVE for emergency fittings — ⭐ which uses one of your three, and is a decision to make at fitout rather than afterwards. ⭐ Confirm the arrangement with us and your electrician before ordering.
⭐ Retail fitouts that rearrange, pop-up and seasonal stores, galleries that rehang, and any tenancy where the fitout will change within the life of the building. ⭐⭐ IN A SHELL-AND-CORE TENANCY IT IS PARTICULARLY USEFUL: the landlord provides track and the tenant hangs both the display lighting and the emergency provision from it, so a fitout change does not become a ceiling job. ⚠ In a fixed layout — an office, a corridor, a stairwell — a conventional fixed emergency fitting is simpler, cheaper and not worse.
| Specification | Value |
|---|---|
| ⭐ What it is | ⭐ An emergency luminaire on a track adaptor |
| ⭐⭐ Why that matters | ⭐ Emergency lighting that moves when the layout does |
| Classification | ⭐ D40 under AS2293.3 — ⭐ it sets the spacing |
| ⭐ vs D63 elsewhere | ⭐ D63 gives wider spacing and more light |
| ⚠ The open question | ⚠ Which circuit? — ⭐ it needs a permanent live |
| ⭐ Usual answer | ⭐ Dedicate one of the three circuits as always-live |
| ⛔ Duration | ⛔ Not published — ⭐ and it is a COMPLIANCE figure |
| ⛔ Output / battery / self-test | ⛔ None published |
| ⛔ Dimensions / warranty | ⛔ Neither published |
| Finishes | Black · White |
D40-classified emergency luminaire on a 3-circuit track adaptor. Black or white. Classification to AS2293.3. ⭐⭐ EMERGENCY LIGHTING THAT MOVES WITH THE SHOP. Emergency luminaires are normally fixed at positions determined by a spacing calculation, which is a problem in retail — a shop that moves its shelving has moved its escape routes, and lighting positioned for the old layout may not serve the new one. A track-mounted fitting slides with the aisles: no electrician, no new penetration, no re-run cable. ⚠ THE QUESTION THE LISTING DOES NOT ANSWER IS WHICH CIRCUIT: an emergency fitting needs a permanent live to charge, and 3-circuit track exists to be switched. ⛔ NO DURATION, OUTPUT, BATTERY OR SELF-TEST DETAIL IS PUBLISHED, and duration is a compliance figure — ask us before specifying it.
Supplied and supported by Lights For You.
Because it moves with the shop. Emergency luminaires are normally fixed at positions determined by a spacing calculation, and once installed they stay — which is a problem in retail, where a shop that moves its shelving has moved its escape routes. A track-mounted fitting slides with the aisles, without an electrician, a new penetration or re-run cable.
One worth understanding. The spacing still has to satisfy the certifier, and a fitting that can move is a fitting that can be moved wrong. Record the compliant positions and check them after any layout change — the flexibility is the benefit and also the risk.
This is the question the listing does not answer. An emergency luminaire needs a permanent live to keep its battery charged, while the whole point of a 3-circuit track is that circuits are switched — a fitting on a circuit switched off overnight is charging only during trading hours. The usual answer is to dedicate one circuit as permanently live for emergency fittings, which uses one of your three and is a decision to make at fitout. Confirm the arrangement with us and your electrician before ordering.
A classification under AS2293.3 where the letter describes the light distribution and the number is a spacing basis — it tells a designer how far apart these can sit and still meet the required floor illuminance. That drives the cost of an emergency scheme more than lumen output does. D40 is the lower of the two classifications in the Domus range; the D63 fittings give wider spacing and more light, which on a large open floor means noticeably fewer fittings.
Nearly everything. No datasheet, no lumen output, no duration, no battery type, no charge time, no dimensions, no weight and no warranty. Its record publishes only a bulb type and an application, which tell a buyer nothing.
The duration, because it is a compliance figure — AS2293 requires a minimum maintained period and it is not something to assume. Whether the unit is self-testing matters nearly as much, because for a fitting on a shop floor it determines who has to test it and how often. We have not estimated either. Ask us before specifying this on a compliance scheme.
In a fixed layout — an office, a corridor, a stairwell — where a conventional fixed emergency fitting is simpler, cheaper and not worse. The track version earns its place where the fitout will change: retail that rearranges, pop-ups, galleries that rehang, and shell-and-core tenancies where the landlord provides track and the tenant hangs both display and emergency lighting from it.
| Brand | Domus Lighting |
|---|---|
| Model / SKUs | Track 3-Circuit Emergency Kit D40 — 66096 Black, 66097 White |
| ⭐⭐ EMERGENCY LIGHTING THAT MOVES WITH THE SHOP | ⭐ Normally it is fixed at calculated positions |
| ⭐ A shop that moves its shelving | ⭐ Has moved its ESCAPE ROUTES |
| ⭐ Track-mounted, it slides with the aisles | ⭐ No electrician · no penetration · no re-run cable |
| ⚠ But a fitting that can move | ⚠ Can be moved WRONG — ⭐ record the compliant positions |
| ⭐ Classification D40 under AS2293.3 | ⭐ The number is a SPACING basis |
| ⭐ Which drives scheme cost | ⭐ More than lumen output does |
| ⭐ D63 elsewhere in the range | ⭐ Wider spacing, more light — ⭐ fewer fittings on a large floor |
| ⚠⚠ THE QUESTION THE LISTING DOES NOT ANSWER | ⚠ WHICH CIRCUIT? — ⭐ it needs a PERMANENT live |
| ⭐ Usual answer | ⭐ Dedicate one of the three as always-live — ⭐ decide at fitout |
| ⛔ Duration NOT published | ⭐ And it is a COMPLIANCE figure under AS2293 |
| ⛔ Nor output, battery, self-test, dimensions or warranty | ⭐ Its record publishes only bulb_type and application |
| Layout | ⭐ Track emergency | Fixed emergency |
|---|---|---|
| ⭐ Retail, rearranged | ⭐ Right | ⚠ Re-work |
| ⭐ Shell-and-core | ⭐ Right | ⚠ Ceiling job |
| Office, corridor | ⚠ Overkill | ⭐ Simpler |
For all warranty claims please ensure you have your proof of purchase at hand, an invoice from your electrician from the installation and check the faulty product is within the applicable warranty period. Warranty is replacement only.
Lights For You is not responsible for damages caused by unprofessional installation, modified products or manipulated by the customer or by any other person not authorised by the manufacturer; as well as by improper use, manipulation and/or short circuits, apparent signs of improper treatment.
Notification of any damages or missing items must be received by Lights For You within seven (7) days of receipt of the product. Please email photos to ashfield@lightsforyou.com.au.
If the product is to be repaired or replaced, it must correspond to the one originally sent by Lights For You and the customer must include the delivery note and/or invoice.
You must lodge a return request via the below request form.
Credits will be issued in the form of store credit or gift voucher and will be equal to the price paid for the product minus the cost of shipping. Store credit vouchers are valid for six months from the date of issuance.
We reserve the right to refuse a return in cases where we cannot be reasonably satisfied that you purchased the product from us or where we are not responsible for the damage in accordance with our Faults & damages policy.
Customers who wish to cancel all or part of an order due to change of mind or incorrectly ordered may do subject to cancelling in within 12 hours, during business hours from time of purchase. Once products have been shipped, you cannot cancel them.