Bar Lights
Batten Lights
Batten Fix Lights(DIY)
Bedside Table Lamps
Cabinet Lights
Ceiling Lights
Chandeliers
Close to Ceiling Light (CTC)
Copper Lights
Emergency Lighting
Fairy Lights
Floor Lamps
High Bay Lights (UFO)
Lamps
Mirror Lights
Oyster Lights
Pendants Lighting
Plaster Wall Lights
Smart Lights
Spot Lights
Table Lamps
Touch Table Lamps
Up/Down Wall Lights
Vanity Lights
Wall Lights
LED Strips
LED Strips Controller
Batten Lights
Bollard Lighting
Brick Lights
Bunker Lights
Coach Lighting
Deck Lights
Driveway Lights
Fairy Lights
Flood Lights
Garden Lighting
Inground Lights
Pathway Lighting
Pillar Mount
Pond Lights
Posts Lights/Top
Outdoor Ceiling Lights
Outdoor Sensor Lights
Outdoor Wall Lights
Solar Lights
Spike Lights
Step Lights
Up/Down Wall Lights
Clearance Sale
LoginCouldn't load pickup availability
The Domus SLENDA-RND 250 is a surface-mounted LED oyster — 250 mm, 8 W or 13 W switchable, 3000/4000/5000 K switchable, IP54, double insulated, in white or black.
| Colour temperature | White | Black | ⭐ Difference |
|---|---|---|---|
| 3000 K | 924 lm | 901 lm | ⭐ −2.5% |
| 4000 K | 960 lm | 933 lm | ⭐ −2.8% |
| 5000 K | 933 lm | 909 lm | ⭐ −2.6% |
⭐ The fitting is made from polypropylene and polystyrene and is double insulated. ⭐⭐ THE PRACTICAL CONSEQUENCE: IT CAN BE INSTALLED WHERE THERE IS NO EARTH WIRE. ⭐ In older Australian housing that is common — a lighting circuit run before earthing at the fitting was standard. ⭐ A Class I metal fitting cannot legally go there without rewiring the circuit; a double-insulated one can. ⭐ On a renovation that single property can be the difference between replacing a light and replacing a circuit. ⭐ It is also why the body is plastic rather than metal, which is a deliberate engineering choice rather than a cost one.
⭐ That distinction is unusual enough to explain. ⭐ A fitting in a house runs a few hours a day; the same fitting in a corridor or a stairwell may run continuously. ⭐ Five years of residential use and three of commercial use are roughly comparable in operating hours, ⭐ so the split is a statement about duty cycle rather than a downgrade. ⭐ If the installation is commercial, the three-year figure is the one that applies regardless of what the residential number says.
| Specification | Value |
|---|---|
| ⭐ Black vs white output | ⭐ Black 2.6% below white ON THIS SIZE — ⚠ 300 mm −0.2%, 400 mm −6.7% |
| Output, white | ⭐ 924 / 960 / 933 lm at 8 W · ⭐ ~1,410–1,504 lm at 13 W |
| Wattage | ⭐ 8 W or 13 W switchable — ⛔ the record lists only 13 |
| Colour temperatures | ⭐ 3000 / 4000 / 5000 K switchable — ⛔ the record lists only two |
| ⭐ Double insulated | ⭐ Installs where there is NO EARTH WIRE |
| IP rating | ⭐ IP54 — ⭐ bathrooms, laundries, coastal |
| Beam angle | ⭐ 100° — ⭐ ~5.7 m circle from a 2.4 m ceiling |
| Colour rendering | CRI ≥80 |
| Dimmable | ⭐ Yes, with a suitable dimmer |
| Warranty | ⭐ 5 years residential · 3 years commercial |
Surface-mounted LED oyster, 250 mm. 8 W or 13 W switchable, 3000/4000/5000 K switchable. 924–960 lm at 8 W (white), 1,410–1,504 lm at 13 W. CRI ≥80, 100° beam. IP54. Double insulated, polypropylene and polystyrene. Dimmable. 50,000 hrs. 5-year residential / 3-year commercial warranty. ⭐⭐ THE BLACK VERSION IS 2.6% DIMMER THAN THE WHITE at the same wattage — published, and but NOT a range-wide constant: the 300 mm measures effectively no difference and the 400 mm about 6.7%. An optical loss would be consistent, so the reflectance explanation we first gave does not survive. The published figures stand and are worth designing to size by size. ⭐ DOUBLE INSULATION IS THE OTHER HEADLINE: it installs where there is no earth wire, which in older housing can be the difference between replacing a light and replacing a circuit.
Supplied and supported by Lights For You.
On this size, by about 2.6%. The datasheet publishes lumens for each housing colour separately, which almost nothing does: at 8W, white gives 924/960/933 lumens across the three colour temperatures and black gives 901/933/909. But it is not a range-wide rule — the 300mm measures effectively no difference and the 400mm about 6.7%, so we report each size's own figures.
We are no longer confident it does, as a rule. We first explained it as a white interior reflecting light that a black one absorbs — but that predicts a consistent loss at every size, and across the three SLENDA sizes the gap runs 2.6%, 0.2% and 6.7%. An 8.8-point spread within one product family reads as separately-measured products carrying ordinary variation rather than an optical mechanism. The published figures stand; the explanation does not.
On one fitting, no — 2.6% is below what the eye detects. Across a lighting calculation for a whole floor it is a real if small deficit, and it is the kind of thing that turns a design that just meets a lux target into one that just misses. Choose black for how it looks, and allow for it if the numbers are tight.
Six configurations in one fitting: 8W or 13W, each at 3000, 4000 or 5000K, running from about 900 to about 1,500 lumens. On a project the real benefit is stock rather than flexibility — one product covers a hallway that wants 900 lumens and a laundry that wants 1,500, so a builder carries one box instead of two.
The switch is set at installation and rarely checked. Two fittings in one room on different settings is obvious and annoying. Set them all before the ceiling goes up, and write the setting down somewhere.
It can be installed where there is no earth wire. In older Australian housing that is common — a lighting circuit run before earthing at the fitting was standard. A Class I metal fitting cannot legally go there without rewiring the circuit; a double-insulated one can. On a renovation that single property can be the difference between replacing a light and replacing a circuit, and it is why the body is plastic rather than metal.
It is a statement about duty cycle rather than a downgrade. A fitting in a house runs a few hours a day; the same fitting in a corridor or stairwell may run continuously, so five years of residential use and three of commercial use are roughly comparable in operating hours. If the installation is commercial, three years is the figure that applies.
| Brand | Domus Lighting |
|---|---|
| Model / SKUs | SLENDA-RND 250 — 23300 White, 23301 Black |
| ⭐⭐ THE BLACK HOUSING IS 2.6% DIMMER | ⭐ At the same wattage — ⭐ and the listing does not say so |
| ⭐ 3000 K | 924 lm white · 901 lm black — ⭐ −2.5% |
| ⭐ 4000 K | 960 lm white · 933 lm black — ⭐ −2.8% |
| ⭐ 5000 K | 933 lm white · 909 lm black — ⭐ −2.6% |
| ⭐ Consistency is what makes it real | ⚠ Not measurement scatter |
| ⭐ The cause | ⭐ A white interior REFLECTS what a black one ABSORBS |
| ⭐ Worth worrying about? | ⭐ Not on one fitting — ⚠ yes across a whole-floor lux calculation |
| ⭐⭐ DOUBLE INSULATED | ⭐ Installs where there is NO EARTH WIRE |
| ⭐ Which in older housing | ⭐ Can be the difference between replacing a light and a circuit |
| ⭐ Switchable | ⭐ 8/13 W × three CCTs = ⭐ six settings, ⭐ one part number |
| ⛔ The record lists only 13 W and two CCTs | ⭐ The sheet has both wattages and all three |
| ⭐ IP54 · 100° beam | ⭐ ~5.7 m circle from a 2.4 m ceiling |
| ⭐ Warranty 5 yr residential / 3 yr commercial | ⭐ A duty-cycle statement, ⚠ not a downgrade |
| At 8 W | White | Black | ⭐ Loss |
|---|---|---|---|
| 3000 K | 924 lm | 901 lm | ⭐ −2.5% |
| 4000 K | 960 lm | 933 lm | ⭐ −2.8% |
| 5000 K | 933 lm | 909 lm | ⭐ −2.6% |
For all warranty claims please ensure you have your proof of purchase at hand, an invoice from your electrician from the installation and check the faulty product is within the applicable warranty period. Warranty is replacement only.
Lights For You is not responsible for damages caused by unprofessional installation, modified products or manipulated by the customer or by any other person not authorised by the manufacturer; as well as by improper use, manipulation and/or short circuits, apparent signs of improper treatment.
Notification of any damages or missing items must be received by Lights For You within seven (7) days of receipt of the product. Please email photos to ashfield@lightsforyou.com.au.
If the product is to be repaired or replaced, it must correspond to the one originally sent by Lights For You and the customer must include the delivery note and/or invoice.
You must lodge a return request via the below request form.
Credits will be issued in the form of store credit or gift voucher and will be equal to the price paid for the product minus the cost of shipping. Store credit vouchers are valid for six months from the date of issuance.
We reserve the right to refuse a return in cases where we cannot be reasonably satisfied that you purchased the product from us or where we are not responsible for the damage in accordance with our Faults & damages policy.
Customers who wish to cancel all or part of an order due to change of mind or incorrectly ordered may do subject to cancelling in within 12 hours, during business hours from time of purchase. Once products have been shipped, you cannot cancel them.
Please refer to the following link to learn more about our policies
Learn MoreThanks for subscribing!
This email has been registered!
| Product | SKU | Product type | Other details |
|---|