Bar Lights
Batten Lights
Batten Fix Lights(DIY)
Bedside Table Lamps
Cabinet Lights
Ceiling Lights
Chandeliers
Close to Ceiling Light (CTC)
Copper Lights
Emergency Lighting
Fairy Lights
Floor Lamps
High Bay Lights (UFO)
Lamps
Mirror Lights
Oyster Lights
Pendants Lighting
Plaster Wall Lights
Smart Lights
Spot Lights
Table Lamps
Touch Table Lamps
Up/Down Wall Lights
Vanity Lights
Wall Lights
LED Strips
LED Strips Controller
Batten Lights
Bollard Lighting
Brick Lights
Bunker Lights
Coach Lighting
Deck Lights
Driveway Lights
Fairy Lights
Flood Lights
Garden Lighting
Inground Lights
Pathway Lighting
Pillar Mount
Pond Lights
Posts Lights/Top
Outdoor Ceiling Lights
Outdoor Sensor Lights
Outdoor Wall Lights
Solar Lights
Spike Lights
Step Lights
Up/Down Wall Lights
Clearance Sale
LoginCouldn't load pickup availability
A replacement LED globe on a twist-lock mains base, running on 240V. This base runs directly on mains, so there is no transformer or driver behind it. The two pins twist and lock a quarter turn - if a globe drops out of a downlight, it is almost always because it was pushed in without being twisted home.
Globes are the one part of a light fitting that is genuinely consumable, and the reason to buy a good one is that a fitting outlives many of them. Getting the base right is the whole job - everything else is a preference.
It draws 5W. The beam is 30°. Colour rendering is ≥80.
This is a colour-changing globe supplied with its remote. Coloured output from any RGB source is dimmer than white at the same wattage, so plan the number of fittings around the colour you will actually use rather than the white figure.
This globe is dimmable. ⚠ On a lamped fitting the DIMMING BEHAVIOUR FOLLOWS THE GLOBE, not the fitting - so a dimmable globe is what makes a dimmed circuit work, and a non-dimmable one will buzz, flicker or refuse to dim no matter what the fitting claims. The dimmer itself should be one rated for LED loads.
An LED globe rarely fails the way a halogen did. What kills it early is heat: the electronics sit in the base, and in a sealed or insulated fitting that heat has nowhere to go. A globe that dies within months in one fitting and lasts for years in another is almost always telling you about the fitting, not the globe.
If a fitting is fully enclosed, check it is rated for that before assuming the globe is at fault. The same applies to insulation packed against a downlight in a ceiling - it traps heat around the very part that is least tolerant of it.
This globe runs on mains, so it needs no transformer or driver behind it. Check the base on the globe you are replacing rather than the shape of the fitting - mains and low-voltage fittings look very similar from below, and the bases are not interchangeable.
Take the old globe with you or photograph its markings. Our team at Lights For You can identify a base from a clear photograph, which is faster than measuring pin spacing.
GU10 - a twist-lock mains base.
No. It runs directly on mains.
Yes, on a dimmer rated for LED loads.
Match the colour temperature to what is already in the room. One globe at a different colour in a run is immediately obvious.
Photograph the markings on the old globe and send them to us - the base is the part that must match exactly.
| Type | Replacement LED globe |
|---|---|
| Lamp base | GU10 |
| Power | 5W |
| Colour | RGB |
| Beam angle | 30° |
| CRI | ≥80 |
| Supply | 240V - no driver required |
| Dimmable | Yes |
| Part number | Base | Power | Supply | Dimmable |
|---|---|---|---|---|
| HV95021-240V | GU10 | 5W | 240V | Yes |
For all warranty claims please ensure you have your proof of purchase at hand, an invoice from your electrician from the installation and check the faulty product is within the applicable warranty period. Warranty is replacement only.
Lights For You is not responsible for damages caused by unprofessional installation, modified products or manipulated by the customer or by any other person not authorised by the manufacturer; as well as by improper use, manipulation and/or short circuits, apparent signs of improper treatment.
Notification of any damages or missing items must be received by Lights For You within seven (7) days of receipt of the product. Please email photos to ashfield@lightsforyou.com.au.
If the product is to be repaired or replaced, it must correspond to the one originally sent by Lights For You and the customer must include the delivery note and/or invoice.
You must lodge a return request via the below request form.
Credits will be issued in the form of store credit or gift voucher and will be equal to the price paid for the product minus the cost of shipping. Store credit vouchers are valid for six months from the date of issuance.
We reserve the right to refuse a return in cases where we cannot be reasonably satisfied that you purchased the product from us or where we are not responsible for the damage in accordance with our Faults & damages policy.
Customers who wish to cancel all or part of an order due to change of mind or incorrectly ordered may do subject to cancelling in within 12 hours, during business hours from time of purchase. Once products have been shipped, you cannot cancel them.
Please refer to the following link to learn more about our policies
Learn MoreThanks for subscribing!
This email has been registered!
| Product | SKU | Product type | Other details |
|---|