Bar Lights
Batten Lights
Batten Fix Lights(DIY)
Bedside Table Lamps
Cabinet Lights
Ceiling Lights
Chandeliers
Close to Ceiling Light (CTC)
Copper Lights
Emergency Lighting
Fairy Lights
Floor Lamps
High Bay Lights (UFO)
Lamps
Mirror Lights
Oyster Lights
Pendants Lighting
Plaster Wall Lights
Smart Lights
Spot Lights
Table Lamps
Touch Table Lamps
Up/Down Wall Lights
Vanity Lights
Wall Lights
LED Strips
LED Strips Controller
Batten Lights
Bollard Lighting
Brick Lights
Bunker Lights
Coach Lighting
Deck Lights
Driveway Lights
Fairy Lights
Flood Lights
Garden Lighting
Inground Lights
Pathway Lighting
Pillar Mount
Pond Lights
Posts Lights/Top
Outdoor Ceiling Lights
Outdoor Sensor Lights
Outdoor Wall Lights
Solar Lights
Spike Lights
Step Lights
Up/Down Wall Lights
Clearance Sale
LoginCouldn't load pickup availability
The Domus STREAM 6-in-1 is a slimline bathroom heater, fan and light — 2,250 W, 240 V, 500 m³/h extraction, ≤48 dB, 595 × 280 mm cutout, with a digital wall controller.
⭐ 3000 K gives 1,500 lm, 4000 K gives 1,850 and 5000 K gives 1,750. ⭐ That is enough to be a bathroom's main light in most cases, which is worth knowing because it changes the rest of the plan — if this unit lights the room, the ceiling needs nothing else except perhaps a vanity light. ⭐ CRI ≥80 is adequate for a bathroom but not for close colour work; if someone does makeup in this room, a separate vanity light at higher CRI is worth having.
⭐ The cutout is 595 × 280 mm and the fascia is 615 × 315 mm — ⭐ so the fascia covers 20 mm each way, which is not a lot of tolerance. ⭐⭐ A 595 mm cutout is longer than the gap between many ceiling joists at 450 mm centres — ⭐ so it may need a joist trimmed and noggins added, which is a framing job rather than an electrical one. ⭐ CHECK THE JOIST DIRECTION AND SPACING BEFORE ORDERING, ⭐ not after the ceiling is up.
⭐ The sheet held against this product could not be confirmed as belonging to it. ⭐ We have used it only where it agrees with the product's own record — the 2,250 W load and the IPX2 rating appear in both. ⭐ The airflow, noise, cutout and lumen figures come from that sheet alone, so treat them as indicative and confirm the cutout with us before you order — it is the one figure that cannot be corrected afterwards. ⛔ No warranty is published for this product at all.
| Specification | Value |
|---|---|
| ⭐⭐ Load | ⭐ 2,250 W = 9.4 A = 94% of a 10 A circuit |
| ⛔ Dedicated circuit | ⛔ Required — ⭐ and nothing on the listing says so |
| ⭐ IP rating | ⭐ IPX2 — ⭐ dripping water only, ⚠ outside the shower zone |
| Extraction | ⭐ 500 m³/h — ⭐ a full air change every ~70 sec |
| ⭐ Noise | ⭐ ≤48 dB — ⭐ the figure that decides whether it gets used |
| ⭐ Cutout | ⭐ 595 × 280 mm — ⚠ may need a joist trimmed |
| Fascia | 615 × 315 mm — ⭐ only 20 mm cover each way |
| Duct | 150 mm — ⭐ 3 m flexible duct and grille included |
| Light output | ⭐ 1,500 / 1,850 / 1,750 lm · CRI ≥80 |
| ⚠ Sheet status | ⚠ Unverifiable — ⭐ used only where the record agrees |
| ⛔ Warranty | ⛔ Not published |
Slimline bathroom heater, fan and light. 2,250 W at 240 V. 500 m³/h extraction, ≤48 dB. 150 mm duct, 3 m flexible duct and exterior grille included. Light 1,500/1,850/1,750 lm across three colour temperatures, CRI ≥80. Digital wall controller. Cutout 595 × 280 mm, fascia 615 × 315 mm. IPX2. ⭐⭐ IT DRAWS 9.4 A — 94% OF A STANDARD 10 A LIGHTING CIRCUIT, ON ITS OWN, BEFORE A SINGLE LIGHT IS CONNECTED. It needs a dedicated circuit and nothing on the listing says so; that gets discovered at rough-in when the cable is already run. ⭐ IPX2 MEANS DRIPPING WATER ONLY, so it belongs in a ceiling position outside the shower zone — normal for a heater, which needs airflow through it, but it means the rating decides the position. ⚠ AND THE 595 mm CUTOUT IS LONGER THAN A 450 mm JOIST GAP — check the framing before ordering.
Supplied and supported by Lights For You.
No. 2,250W at 240V is 9.4 amps, and a standard 10A lighting circuit carries 2,400W — so this one appliance is 94% of that circuit before a single light is connected to it. It needs a dedicated circuit, and nothing on the listing says so. Tell your electrician before the walls close: adding a circuit at rough-in is routine, adding one afterwards means chasing walls.
No. The load is almost entirely the heating elements — the fan motor is 60W and the light a few more. Running the fan and light alone draws almost nothing; it is only when the heat is on that the circuit is loaded.
The X means ingress of solids was not tested — not that there is no protection, but that no figure is claimed. The 2 means protection against dripping water when the unit is tilted up to 15 degrees. That is the lowest water rating in common use for a bathroom product.
A ceiling position outside the shower zone. It is not a fitting for directly above a shower or a bath. That is normal for this class of product rather than a deficiency — a heater needs airflow through it, and a fully sealed heater is a contradiction — but it does mean the rating decides the position rather than where the heat would be most welcome. Confirm the zone with your electrician against the current wiring rules.
Comfortably. A typical bathroom of about 10 cubic metres is a complete air change roughly every 70 seconds, which clears steam quickly enough to stop it reaching the ceiling and the mirror. But the ducting is what delivers it: 150mm, kept short and straight. Every bend costs airflow and adds noise, and a long flexible duct with sags in it can halve the effective extraction.
Because it determines whether the fan gets turned on. An extraction fan people find unpleasant is a fan that runs for two minutes instead of twenty, and mould follows. 48dB is roughly the level of quiet conversation — noticeable but not intrusive.
The ceiling framing. The cutout is 595 x 280mm and the fascia 615 x 315mm, so there is only 20mm of cover each way. A 595mm cutout is longer than the gap between many ceiling joists at 450mm centres, so it may need a joist trimmed and noggins added — a framing job rather than an electrical one. Check the joist direction and spacing before ordering, not after the ceiling is up.
| Brand | Domus Lighting |
|---|---|
| Model / SKU | STREAM 6-in-1 — 56083 (White) |
| ⭐⭐ 2,250 W = 9.4 A | ⭐ 94% of a standard 10 A lighting circuit |
| ⛔⛔ IT NEEDS A DEDICATED CIRCUIT | ⛔ And nothing on the listing says so |
| ⭐ Tell the electrician BEFORE the walls close | ⭐ Routine at rough-in — ⚠ chasing walls afterwards |
| ⭐ The load is almost all heating elements | ⭐ Fan motor 60 W — ⭐ fan and light alone draw little |
| ⭐ IPX2 — ⭐ the X means solids NOT TESTED | ⭐ Not that there is no protection |
| ⭐ The 2 = dripping water, tilted to 15° | ⚠ The lowest water rating in common bathroom use |
| ⭐ So: a ceiling position OUTSIDE the shower zone | ⭐ Normal for a heater — ⭐ it needs airflow through it |
| ⭐ Extraction 500 m³/h | ⭐ A full air change every ~70 sec in a 10 m³ bathroom |
| ⭐⭐ ≤48 dB IS THE MORE IMPORTANT FIGURE | ⭐ It decides whether the fan gets TURNED ON |
| ⚠ Ducting delivers the numbers | ⭐ 150 mm short and straight — ⚠ sags can halve extraction |
| ⚠ Cutout 595 × 280 mm | ⚠ LONGER than a 450 mm joist gap — ⭐ check framing first |
| ⚠ Sheet flagged unverifiable · ⛔ no warranty published | ⭐ Used only where the record agrees |
| Figure | Value | ⭐ Consequence |
|---|---|---|
| ⭐ Load | ⭐ 9.4 A | ⛔ Dedicated circuit |
| ⭐ IPX2 | Dripping only | ⚠ Outside the shower zone |
| ⚠ Cutout | 595 mm | ⚠ Check the joists |
| ⭐ Noise | ≤48 dB | ⭐ It gets used |
For all warranty claims please ensure you have your proof of purchase at hand, an invoice from your electrician from the installation and check the faulty product is within the applicable warranty period. Warranty is replacement only.
Lights For You is not responsible for damages caused by unprofessional installation, modified products or manipulated by the customer or by any other person not authorised by the manufacturer; as well as by improper use, manipulation and/or short circuits, apparent signs of improper treatment.
Notification of any damages or missing items must be received by Lights For You within seven (7) days of receipt of the product. Please email photos to ashfield@lightsforyou.com.au.
If the product is to be repaired or replaced, it must correspond to the one originally sent by Lights For You and the customer must include the delivery note and/or invoice.
You must lodge a return request via the below request form.
Credits will be issued in the form of store credit or gift voucher and will be equal to the price paid for the product minus the cost of shipping. Store credit vouchers are valid for six months from the date of issuance.
We reserve the right to refuse a return in cases where we cannot be reasonably satisfied that you purchased the product from us or where we are not responsible for the damage in accordance with our Faults & damages policy.
Customers who wish to cancel all or part of an order due to change of mind or incorrectly ordered may do subject to cancelling in within 12 hours, during business hours from time of purchase. Once products have been shipped, you cannot cancel them.
Please refer to the following link to learn more about our policies
Learn MoreThanks for subscribing!
This email has been registered!
| Product | SKU | Product type | Other details |
|---|