Bar Lights
Batten Lights
Batten Fix Lights(DIY)
Bedside Table Lamps
Cabinet Lights
Ceiling Lights
Chandeliers
Close to Ceiling Light (CTC)
Copper Lights
Emergency Lighting
Fairy Lights
Floor Lamps
High Bay Lights (UFO)
Lamps
Mirror Lights
Oyster Lights
Pendants Lighting
Plaster Wall Lights
Smart Lights
Spot Lights
Table Lamps
Touch Table Lamps
Up/Down Wall Lights
Vanity Lights
Wall Lights
LED Strips
LED Strips Controller
Batten Lights
Bollard Lighting
Brick Lights
Bunker Lights
Coach Lighting
Deck Lights
Driveway Lights
Fairy Lights
Flood Lights
Garden Lighting
Inground Lights
Pathway Lighting
Pillar Mount
Pond Lights
Posts Lights/Top
Outdoor Ceiling Lights
Outdoor Sensor Lights
Outdoor Wall Lights
Solar Lights
Spike Lights
Step Lights
Up/Down Wall Lights
Clearance Sale
LoginCouldn't load pickup availability
The Domus EVAC-D63-SM is a 3.5 W surface-mounted non-maintained emergency light — D63 classification, 4500 K, LiFePO4 battery, 180 × 180 mm, complying with AS 2293.3-2005 + AMD 1&2 Annex C. White or black.
The recessed EVAC-D63 publishes 380 lm. ⛔ This surface-mounted version publishes none — not in the record, not in the parsed datasheet.
3.5 W surface-mounted non-maintained LED emergency light. D63 classification. 4500 K, 140° beam. 180 × 180 mm. LiFePO4 battery with polarity-reversal protection. Large terminal, PA16. 240 V, IP20. Complies with AS 2293.3-2005 + AMD 1&2 Annex C, EMC compliant. White or black. ✅ Warranty 4 years including the battery. ⛔ No lumen figure is published for this version in any source — the recessed EVAC-D63 gives 380 lm from the same 3.5 W engine. ⛔ The D63 classification and the battery duration are on the sheet or absent, not in any field.
Supplied and supported by Lights For You.
When the ceiling cannot or should not be cut. A concrete soffit, a fire-rated ceiling you must not penetrate, or a finished plaster ceiling you do not want to open — all point to surface mounting. On an emergency retrofit that is often the real constraint: cutting into a fire-rated ceiling means making good the rating, and a surface fitting sidesteps it entirely. The trade-off is appearance: at 180 × 180mm this is a visible object, so it wants a considered position rather than wherever the spacing table lands.
No lumen figure is published for this version in any source — not in the record and not in the parsed datasheet. The recessed EVAC-D63 gives 380lm from the same 3.5W engine and the same D63 classification, so a similar figure is likely, but we are not going to publish that number as this one's because the optic and housing differ. Worth knowing that on an emergency light the classification matters more than the lumens anyway: D63 is what AS 2293.1 turns into a spacing table, and that is what you count fittings with.
Four years, including the battery — recorded on this listing and matching its datasheet. Worth flagging that its recessed twin, the EVAC-D63-REC, records two years against the same four-year sheet, so if you are comparing the two the recessed one looks like a shorter-warranty product and is not. "Including battery" is the phrase that matters: the BOLT emergency battens here split their term three years on the fitting and one on the battery, and the battery is what ages and what fails the periodic discharge test.
It sets the spacing. The classification describes the shape and reach of the emergency light on the floor, and AS 2293.1 converts it into a spacing table — so it is what tells a designer how many fittings a corridor needs. D63 covers more ground than D40, so fewer fittings cover the same path of travel. It is on the datasheet and in no product field, which is the single most consequential omission on an emergency listing.
Not stated in any source we hold. The required duration comes from your building's classification and your electrical designer, and the fitting's figure has to be checked against it — so this is one to settle before it goes on a drawing. Ask us and we will get it from Domus in writing.
A generous terminal block for the incoming wiring, noted on the datasheet. It matters more on a surface fitting than a recessed one, because the cable arrives on the surface rather than through a hole and there is less room to dress it. A larger terminal makes the connection easier and tidier, which on a run of emergency fittings across a corridor adds up.
No — it is non-maintained, which means it is off in normal use and comes on only when the mains fails. That is what most Australian emergency lighting is, because the fitting exists to get people out rather than to light the space. If your drawing calls for maintained, where the fitting is lit continuously and stays lit on battery, this is the wrong product and we will find you one.
| Brand | Domus Lighting |
|---|---|
| Model / SKUs | EVAC-D63-SM — 66044 White, 66045 Black |
| Type | Surface-mounted non-maintained LED emergency light |
| ✅ Warranty | 4 years INCLUDING THE BATTERY — ⭐ recorded correctly here, where the recessed twin records 2 |
| ⛔ Classification | D63 — ⛔ on the datasheet, in no field. ⭐ This is what sets fitting spacing |
| Wattage | 3.5W |
| ⛔ Lumen output | Not published for this version in any source (the recessed EVAC-D63 gives 380lm) |
| Colour temperature | 4500K |
| Beam angle | 140° |
| Dimensions | 180 × 180mm — ⛔ on the datasheet, in no field |
| Emergency mode | Non-maintained — ⚠ off in normal use |
| Battery | LiFePO4, with ⭐ polarity-reversal protection |
| ⛔ Duration | Not stated in any source — ask us |
| Compliance | AS 2293.3-2005 + AMD 1&2 Annex C; EMC compliant |
| Terminal | Large terminal, PA16 — ⭐ easier dressing for surface wiring |
| IP rating | IP20 |
| Finishes | White, Black |
| Ceiling | Surface (this one) | Recessed EVAC-D63 |
|---|---|---|
| Concrete soffit | ⭐ Yes — no penetration | ⛔ Needs a cutout |
| Fire-rated ceiling | ⭐ Yes — rating untouched | ⚠ Must be made good |
| Finished plaster, retrofit | ✅ Yes | ✅ Adjustable dish 95/145mm |
| Where appearance matters | ⚠ 180 × 180mm, visible | ⭐ Flush |
For all warranty claims please ensure you have your proof of purchase at hand, an invoice from your electrician from the installation and check the faulty product is within the applicable warranty period. Warranty is replacement only.
Lights For You is not responsible for damages caused by unprofessional installation, modified products or manipulated by the customer or by any other person not authorised by the manufacturer; as well as by improper use, manipulation and/or short circuits, apparent signs of improper treatment.
Notification of any damages or missing items must be received by Lights For You within seven (7) days of receipt of the product. Please email photos to ashfield@lightsforyou.com.au.
If the product is to be repaired or replaced, it must correspond to the one originally sent by Lights For You and the customer must include the delivery note and/or invoice.
You must lodge a return request via the below request form.
Credits will be issued in the form of store credit or gift voucher and will be equal to the price paid for the product minus the cost of shipping. Store credit vouchers are valid for six months from the date of issuance.
We reserve the right to refuse a return in cases where we cannot be reasonably satisfied that you purchased the product from us or where we are not responsible for the damage in accordance with our Faults & damages policy.
Customers who wish to cancel all or part of an order due to change of mind or incorrectly ordered may do subject to cancelling in within 12 hours, during business hours from time of purchase. Once products have been shipped, you cannot cancel them.
Please refer to the following link to learn more about our policies
Learn MoreThanks for subscribing!
This email has been registered!
| Product | SKU | Product type | Other details |
|---|